--. 0

Product

 [XR3660]  Rail-Mounted 4-Channel Illuminance Recorder

XR3660

Technical Parameters

Technical parameterParameter value
BrandXUNCHIP
Illuminance measuring range0~65535Lux
Illuminance allow deviation±7%
Repeatability test±5%
Illuminance detection chipImport digital
Wavelength range380nm~730nm
Communication InterfaceRS485
PowerDC9~24V 1A
Running temperature-30~80℃
Working humidity5%RH~90%RH

Product Size

XR3660

software to test

XR3660 XR3660 XR3660 XR3660 XR3660

Wiring instructions

Why choose this product?

XR3660

How to use software?

XR3660 XR3660 XR3660 XR3660 XR3660

Why choose this product?

XR3660 XR3660 XR3660 XR3660 XR3660 XR3660

How to use?

XR3660

Application solution

XR3660

Product List

XR3660

Pictures

XR3660 XR3660 XR3660

Communication Protocol

    The product uses the RS485 MODBUS-RTU standard protocol format, and all operation or reply commands are in hexadecimal data. When the device leaves the factory, the default device address is 1, and the default baud rate is: for modules and non-recording instruments: 9600, 8, n, 1 (for the recorder series products, the default is: 115200, 8, n, 1).
1. Read data (Function code 0x03)
    The inquiry frame (in hexadecimal). Example of sending: To query 1 piece of data of device No. 1, the host computer sends the command: 01 03 00 00 00 04 44 09 .
Address Function code Starting address Data length Checksum
010300 0000 0444 09
    For a correct inquiry frame, the device will respond with data: 01 03 08 02 1B 00 00 00 00 00 00 BF F , and the response format is:
Address Function code LengthData 1Data 2Data 3Data 4 Checksum
0103 0802 1802 1902 1A02 1B BF F
    Data description: The data in the command is in hexadecimal. Taking Data 1 as an example, 02 18 converted to decimal value is 536. Assuming the data magnification factor is 100, then the true value is 536/100 = 5.36, and the others can be deduced by analogy.
2. Common Data Address Table
Configuration Address Register Address Register Description Data Type Value Range
4000100 00光照Read Only0~65535
4000200 01光照Read Only0~65535
4000300 02光照Read Only0~65535
4000400 03光照Read Only0~65535
4010100 64 Model Code Read-only 0~59999
4010200 65 Total Number of Measuring Points Read-only 1~1600
4010300 66 Device Address Read/Write 1~249
4010400 67 Baud Rate Read/Write 0~6
4010500 68 Communication Mode Read/Write 1 Query
2 Active Upload4010600 69 Protocol Type Read/Write
1 MODBUS-RTU Others Unused

software for test product
After downloading, please read the readme.txt documentation

0

software for test product
After downloading, please read the readme.txt documentation

0

Data and Software

 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: XR3660

WeChat: 13918126020

SKYPE: SOOBUU

Phone: +86-021-66862075

QQ1: 71182854 QQ2:613035997