--. 0

Product

 [XM8189]  Polycarbon wind speed and wind direction integrated sensor

XM8189

Technical Parameters

Technical parameterParameter value
BrandXUNCHIP
Wind speed range0~30m/s
Start wind0.2m/s
Wind speed accuracy±3%
Shell materialABS
Wind direction range0~360°
Wind direction resolution1.0°
InterfaceRS485/4-20mA/DC0-5V
PowerDC12~24V 1A
Running temperature-30~85℃

Product Selection

    Product DesignRS485,4-20mA,DC0-5VMultiple output methods, the products are divided into the following models depending on the output method.
Product model output method
XM8189BRS485总线
XM8189M4-20mA
XM8189V5DC0-5V

Product Size

XM8189 XM8189 XM8189 XM8189 XM8189 XM8189

Why choose this product?

XM8189 XM8189 XM8189 XM8189

How to use?

XM8189

Product List

XM8189

Pictures

XM8189 XM8189 XM8189

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
    Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 02 C4 0B .
Address Function Code Start Address Data Length Check Code
010300 0000 02C4 0B
    For the correct query frame, the device will respond with data: 01 03 04 00 7A 00 00 DB EA , response format:
Address Function Code LengthData 1Data 2Check Code
0103 0400 7900 7A DB EA
    Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
2. Common data address table
Configuration Address Register Address Register Description Data Type Value Range
4000100 00塑料wind speedRead Only0~65535
4000200 01360conductivityRead Only0~65535
4010100 64Model CodeRead/Write0~65535
4010200 65 total number of measuring points read/write 1~20
4010300 66device addressread/write1~249
4010400 67baud rateread/write0~6
4010500 68communication moderead/write1~4
4010600 69protocol typeread/write1~10

1. and current computing relationship

  For example, the range is 0~30, the analog output is 4~20mA current signal, and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)Value () Calculation Process
40.0(30-0)*(4-4)÷(20-4)+0
51.9(30-0)*(5-4)÷(20-4)+0
63.8(30-0)*(6-4)÷(20-4)+0
75.6(30-0)*(7-4)÷(20-4)+0
87.5(30-0)*(8-4)÷(20-4)+0
99.4(30-0)*(9-4)÷(20-4)+0
1011.3(30-0)*(10-4)÷(20-4)+0
1113.1(30-0)*(11-4)÷(20-4)+0
1215.0(30-0)*(12-4)÷(20-4)+0
1316.9(30-0)*(13-4)÷(20-4)+0
1418.8(30-0)*(14-4)÷(20-4)+0
1520.6(30-0)*(15-4)÷(20-4)+0
1622.5(30-0)*(16-4)÷(20-4)+0
1724.4(30-0)*(17-4)÷(20-4)+0
1826.3(30-0)*(18-4)÷(20-4)+0
1928.1(30-0)*(19-4)÷(20-4)+0
2030.0(30-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 11.5。

2. and current computing relationship

  For example, the range is 0~360, the analog output is 4~20mA current signal, and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)Value () Calculation Process
40.0(360-0)*(4-4)÷(20-4)+0
522.5(360-0)*(5-4)÷(20-4)+0
645.0(360-0)*(6-4)÷(20-4)+0
767.5(360-0)*(7-4)÷(20-4)+0
890.0(360-0)*(8-4)÷(20-4)+0
9112.5(360-0)*(9-4)÷(20-4)+0
10135.0(360-0)*(10-4)÷(20-4)+0
11157.5(360-0)*(11-4)÷(20-4)+0
12180.0(360-0)*(12-4)÷(20-4)+0
13202.5(360-0)*(13-4)÷(20-4)+0
14225.0(360-0)*(14-4)÷(20-4)+0
15247.5(360-0)*(15-4)÷(20-4)+0
16270.0(360-0)*(16-4)÷(20-4)+0
17292.5(360-0)*(17-4)÷(20-4)+0
18315.0(360-0)*(18-4)÷(20-4)+0
19337.5(360-0)*(19-4)÷(20-4)+0
20360.0(360-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 94。

1. and DC0-5Vvoltage computing relationship

  For example, the range is 0~30, the analog output is 0~5V DC0-5Vvoltage signal, and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is range upper limit, A1 is the lower limit of the range, B2 is DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read value, and C is the calculated DC0-5Vvoltage value. The list of commonly used values is as follows:
DC0-5Vvoltage(V)Value () Calculation Process
00.0(30-0)*(0-0)÷(5-0)+0
16.0(30-0)*(1-0)÷(5-0)+0
212.0(30-0)*(2-0)÷(5-0)+0
318.0(30-0)*(3-0)÷(5-0)+0
424.0(30-0)*(4-0)÷(5-0)+0
530.0(30-0)*(5-0)÷(5-0)+0
    As shown in the above formula, when measuring 2.5V, current DC0-5Vvoltage is 15。

2. and DC0-5Vvoltage computing relationship

  For example, the range is 0~360, the analog output is 0~5V DC0-5Vvoltage signal, and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is range upper limit, A1 is the lower limit of the range, B2 is DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read value, and C is the calculated DC0-5Vvoltage value. The list of commonly used values is as follows:
DC0-5Vvoltage(V)Value () Calculation Process
00.0(360-0)*(0-0)÷(5-0)+0
172.0(360-0)*(1-0)÷(5-0)+0
2144.0(360-0)*(2-0)÷(5-0)+0
3216.0(360-0)*(3-0)÷(5-0)+0
4288.0(360-0)*(4-0)÷(5-0)+0
5360.0(360-0)*(5-0)÷(5-0)+0
    As shown in the above formula, when measuring 2.5V, current DC0-5Vvoltage is 180。
software for test product
After downloading, please read the readme.txt documentation

Data and Software
software for test product
Data and Software
software for test product
After downloading, please read the readme.txt documentation

Data and Software

 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: XM8189

WeChat: 13918126020

SKYPE: SOOBUU

Phone: +86-021-66862075

QQ1: 71182854 QQ2:613035997